Diesel Generator

Compare Diesel Generator Models

Key specifications side by side, taken from each product's data sheet. Open a model for its full specification table and configuration options.

ModelEngine ModelRated PowerMax PowerVoltageFrequencyDisplacementFuel TankRun Time
Double Door Cabinet Silent Diesel Generator 11.0-13.0kw2V92F / 2V95F11 / 13 kW12 / 14 kW220V/380V50 Hz997 / 1247 cc25 L6.5 / 5.5 h
Electric Start Open Frame Diesel Generator 11.5-13.5kw2V92F / 2V95F11.5 / 13.5 kW12.5 / 14.5 kW220V/380V50 Hz997 cc27 L7 / 6 h
Freezer Cabinet Silent Diesel Generator 4.2-8.0kw186FA – 1100F4.2 – 8.0 kW4.5 – 8.5 kW220V/380V50 Hz418 – 659 cc16 / 25 L8.5 – 8.6 h
Loaf Cabinet Silent Diesel Generator 4.2-6.0kw186FA / 188F / 192F / 195F4.2 / 4.5 / 5.5 / 6.0 kW4.5 / 5.0 / 6.0 / 6.5 kW220V/380V50 Hz418 / 456 / 498 / 531 cc16 L8.5 / 7.7 / 6.5 / 6 h
Manual Open Frame Diesel Generator 2.8kw178F2.8 kW3.0 kW220V50 Hz296 cc12.5 L10 h
Manual Open Frame Diesel Generator 4.6-6.5kw186FA / 188F / 192F / 195F4.6 / 5.0 / 6.0 / 6.5 kW5.0 / 5.5 / 6.5 / 7.0 kW220V/380V50 Hz418 / 456 / 498 / 531 cc12.5 L7.7 / 6.5 / 5.9 / 5.6 h
Old Square Cabinet Silent Diesel Generator 4.2-6.0kw186FA / 188F / 192F / 195F4.2 / 4.5 / 5.5 / 6.0 kW4.5 / 5.0 / 6.0 / 6.5 kW220V/380V50 Hz418 / 456 / 498 / 531 cc16 L8.5 / 7.7 / 6.5 / 6 h
Silent Diesel Generator 4.2-6.0kw186FA / 188F / 192F / 195F4.2 / 4.5 / 5.5 / 6.0 kW4.5 / 5.0 / 6.0 / 6.5 kW220V/380V50 Hz418 / 456 / 498 / 531 cc16 L8.5 / 7.7 / 6.5 / 6 h

What Is a Diesel Generator Used For?

A diesel generator is chosen when the machine has to run for hours rather than minutes. Farms, workshops, telecom sites, construction compounds and rural premises with unreliable mains all buy for the same reason: the unit must carry a load through a long shift without constant attention.

That is the practical difference from a gasoline generator. Gasoline suits occasional and portable duty; diesel suits sustained duty, and the economics only make sense once the running hours are high enough to matter.

For bulk buyers, the question worth asking the customer is how many hours per week the machine actually runs. Below a certain threshold a diesel generator is an expensive way to buy a feature nobody uses. Above it, nothing else will do the job.

WENXIN manual-open-frame-2-8kw diesel generator, main view
Manual Open Frame Diesel Generator 2.8kw — one of the configurations listed on this page.

Open Frame or Silent: Which Diesel Generator Should You Stock?

Open frame units are simpler, easier to service and lighter to move. They suit farms, sites and workshops where noise is not the deciding factor and access for maintenance is.

Silent units are enclosed and intended for places where the machine sits near people: premises with neighbours, hotels, clinics, offices and residential backup. The enclosure that reduces noise also affects cooling and access, which is why our silent range carries a larger fuel tank than the equivalent open frame configuration.

Distributors serving mixed markets usually need both. The useful sales question is not what the customer prefers but where the machine will physically stand, because that decides the answer more reliably than any preference does.

WENXIN manual-open-frame-4-6-6-5kw diesel generator, main view
Manual Open Frame Diesel Generator 4.6-6.5kw — a further view of the same range.

How Do You Match a Diesel Generator to the Load and the Run Time?

Size for the load including anything that draws extra current at start-up, then check that the fuel tank supports the intended run time. These two get treated as separate questions and they are not: within our range, run time falls as rated power rises from the same tank, so the larger unit will need refuelling sooner under load.

That trade is visible across our own configurations. Higher-output models in the same family run for fewer hours per fill than the smaller ones, because the tank did not grow with the engine. Buyers who size only for peak load are frequently surprised by this on the first night of use.

Where welding capability is needed on the same site, a welder generator covers both jobs in one machine. Voltage, frequency and starting method must match the destination market, and cannot be adjusted after shipping. Confirm them at quotation stage rather than at the port.

WENXIN electric-start-open-frame-11-5-13-5kw diesel generator, main view
Electric Start Open Frame Diesel Generator 11.5-13.5kw — full specifications on the product page.

What Do Diesel Generator Buyers Complain About Most?

Two things: fuel quality and service intervals. Diesel is less forgiving of poor storage than gasoline, and a machine that runs long hours reaches its service points faster than customers expect. Both are avoidable with clear guidance at the point of sale.

The practical answer for a distributor is to supply filters and common wear parts alongside the machine, and to be explicit about the maintenance schedule rather than leaving it in the manual. A diesel generator that is easy to service locally stays in use; one that is not becomes someone else’s problem after the first fault.

WENXIN supplies diesel generators in open frame and silent configurations across a range of outputs, with OEM and ODM support for brand, colour, packaging and specification. Tell us the run hours and where the machine will stand, and we will point at the configurations that suit it.

Frequently Asked Questions

What is a diesel generator used for?

A diesel generator is commonly used for backup power, farm use, construction sites, workshops, small businesses, and emergency power supply where stable and long-running power is required.

What is the difference between a diesel generator and a gasoline generator?

Diesel generators usually offer better fuel efficiency, longer running performance, and are suitable for heavy-duty or long-time use. Gasoline generators are often lighter and more suitable for portable or occasional use.

Can I customize the diesel generator with my own logo and packaging?

Yes. We support OEM/ODM customization, including logo, color, control panel, voltage, packaging, and other requirements based on bulk order needs.

What certificates are available for diesel generators?

Certificates such as CE, RoHS, and EPA can be supported for diesel generators. Certificate availability may vary by model and destination market. Additional certification support is available upon request.

How do I choose the right diesel generator model?

You can choose based on rated power, voltage, starting method, fuel tank capacity, running time, noise level, and application. Contact us with your power requirements, and our team can recommend a suitable model.

Related Articles

Need OEM/ODM or Wholesale Pricing?

Tell us your target market, order quantity and customization requirements — our team will reply within 24 hours with specifications, packaging options and factory pricing.

Send Inquiry